Raw hysteresis loops for this experiment are given in this folder in the file names starting with 'Ni in KOH'. Note that raw hysteresis loop files have the input voltage of the magnet as the first column, which can be converted into magnetic field in mT using the calibration equation field(mT)=3.94302*(field(V))-7.5804E-4. The suffix indicates the respective reduction potential in the graph, loop recorded at the open circuit potential (-0.05 V) is labelled 'OCP'. MOKE intensities in the column 'GrayLevel' were normalized to values between 0 and 1 for the graph.